Klear Human HRP Polymer Detection for HUMAN antibody on HUMAN tissue
IHC Kits and Reagents
Klear Human HRP Polymer Detection for HUMAN antibody on HUMAN tissue
Polink-1 HRP Polymer and AP polymer detection for MOUSE antibody on MOUSE tissue
Klear Mouse HRP Polymer Detection for MOUSE antibody on MOUSE tissue
Polink-1 HRP Polymer and AP polymer detection for MOUSE antibody on MOUSE tissue
Klear Mouse HRP Polymer Detection for MOUSE antibody on MOUSE tissue
Aqueous mounting medium for preserving fluorescence of tissue and cell smears. This mounting medium is fortified with DAPI which is a counterstain for DNA.
Double Staining Kit for MOUSE and RABBIT Primary Antibodies on human tissue
Antibody Diluent Solution
Polink-2 Plus HRP Polymer Detection for RABBIT antibody on human or animal tissue
Polink-1 HRP Polymer Detection for RABBIT antibody on human or animal tissue
Polink-2 Plus HRP Polymer Detection for MOUSE antibody on human or animal tissue (non-rodent)
Polink-2 HRP Polymer Detection for MOUSE and RABBIT antibodies on human tissue
Polink-1 AP Polymer Detection for RABBIT antibody on human or animal tissue
Antibody Diluent Solution

















![IHC staining of FFPE mouse testis tissue within normal limits using mouse anti-PCNA polyclonal antibody and Klear Mouse HRP for DAB detection kit [D52-18]. The brown stain indicates positive stain and blue is the counter stain. It is mounted using a permanent organic mounting medium [E37-100].](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52.jpg?browse)
![Klear Mouse-HRP DAB D52-110 used to detect Abat sku [UM800070] clone UMAB178 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-101.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Abat sku [UM800070] clone UMAB178 on mouse lung bronchus. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-102.jpg?browse)
![Klear Mouse-HRP DAB D52-110 used to detect Aldh1 sku [UM500039] clone UMAB43 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-103.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Bcl2 sku [UM800117] clone UMAB225 on mouse lung bronchus. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:400.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-104.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Bcl2 sku [UM800117] clone UMAB225 on mouse lung smooth muscle. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:400.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-105.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse lung. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-106.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse skin. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-107.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse spleen. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-108.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-109.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse lung. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-110.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse skin. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-111.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse spleen. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-112.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Ercc1 sku [UM500008] clone 4F9 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-113.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Ercc1 sku [UM500011] clone 2E12 on mouse kidney. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-114.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Ercc1 sku [UM500011] clone 2E12 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-115.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Ercc1 sku [UM500011] clone 2E12 on mouse lung. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-116.jpg?browse)
![Klear Mouse-HRP DAB 52-110 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-110-117.jpg?browse)
![Klear Mouse-HRP DAB D52-18 used to detect Abat sku [UM800070] clone UMAB178 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-101.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Abat sku [UM800070] clone UMAB178 on mouse lung bronchus. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-102.jpg?browse)
![Klear Mouse-HRP DAB D52-18 used to detect Aldh1 sku [UM500039] clone UMAB43 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-103.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Bcl2 sku [UM800117] clone UMAB225 on mouse lung bronchus. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:400.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-104.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Bcl2 sku [UM800117] clone UMAB225 on mouse lung smooth muscle. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:400.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-105.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse lung. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-106.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse skin. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-107.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse spleen. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-108.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-109.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse lung. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-110.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse skin. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-111.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse spleen. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-112.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Ercc1 sku [UM500008] clone 4F9 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-113.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Ercc1 sku [UM500011] clone 2E12 on mouse kidney. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-114.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Ercc1 sku [UM500011] clone 2E12 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-115.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Ercc1 sku [UM500011] clone 2E12 on mouse lung. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-116.jpg?browse)
![Klear Mouse-HRP DAB 52-18 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-18-117.jpg?browse)

![Klear Mouse-HRP DAB [D52-60] used to detect Abat sku [UM800070] clone UMAB178 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-101.jpg?browse)

![Klear Mouse-HRP DAB 52-60 used to detect Abat sku [UM800070] clone UMAB178 on mouse lung bronchus. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-102.jpg?browse)
![Klear Mouse-HRP DAB [D52-60] used to detect Aldh1 sku [UM500039] clone UMAB43 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-103.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Bcl2 sku [UM800117] clone UMAB225 on mouse lung bronchus. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:400.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-104.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Bcl2 sku [UM800117] clone UMAB225 on mouse lung smooth muscle. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:400.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-105.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse lung. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-106.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse skin. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-107.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse spleen. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-108.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-109.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse lung. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-110.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse skin. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-111.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse spleen. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-112.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Ercc1 sku [UM500008] clone 4F9 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-113.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Ercc1 sku [UM500011] clone 2E12 on mouse kidney. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-114.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Ercc1 sku [UM500011] clone 2E12 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-115.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Ercc1 sku [UM500011] clone 2E12 on mouse lung. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-116.jpg?browse)
![Klear Mouse-HRP DAB 52-60 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-60d-117.jpg?browse)
![Klear Mouse-HRP DAB D52-6 used to detect Abat sku [UM800070] clone UMAB178 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-101.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Abat sku [UM800070] clone UMAB178 on mouse lung bronchus. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-102.jpg?browse)
![Klear Mouse-HRP DAB D52-6 used to detect Aldh1 sku [UM500039] clone UMAB43 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-103.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Bcl2 sku [UM800117] clone UMAB225 on mouse lung bronchus. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:400.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-104.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Bcl2 sku [UM800117] clone UMAB225 on mouse lung smooth muscle. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:400.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-105.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse lung. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-106.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse skin. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-107.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse spleen. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-108.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-109.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse lung. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-110.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse skin. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-111.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Ctnnb1 sku [UM500015] clone UMAB15 on mouse spleen. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-112.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Ercc1 sku [UM500008] clone 4F9 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-113.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Ercc1 sku [UM500011] clone 2E12 on mouse kidney. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-114.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Ercc1 sku [UM500011] clone 2E12 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-115.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Ercc1 sku [UM500011] clone 2E12 on mouse lung. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-116.jpg?browse)
![Klear Mouse-HRP DAB 52-6 used to detect Cdh2 sku [UM500023] clone UMAB23 on mouse liver. To achieve optimal staining HIER buffer Accel was done for 10 minutes in a pressure cooker and primary antibody was diluted 1:100.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d52-6-117.jpg?browse)


![IHC staining of FFPE human tonsil tissue within normal limits using mouse anti-B cell and rabbit anti-CD3 polyclonal antibodies and Polink DS-MR-Hu A1 detection kit [DS201A-18]. The red (Rabbit anti-CD3) and brown (Mouse anti-B cell) stain indicate positive stain and blue background is the counter stain. It is mounted using a permanent aqueous mounting medium [E03-18].](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/ds201a.jpg?browse)


![IHC staining of FFPE human pancreas tissue within normal limits using rabbit anti-glucagon polyclonal antibody and Polink-2 Plus HRP Rabbit for DAB detection kit [D39-18]. The brown stain indicates positive stain and blue is the counter stain. It is mounted using a permanent organic mounting medium [E37-100].](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d39.jpg?browse)


![Human tonsil with rabbit anti FoxP1 (clone EP137) using Polink1 (D13-110) rabbit polymer detection and HIER Accel ([B22C-125])for was used 10 minutes pressure cooker. Primary antibody was incubated 1 hour; Polink-1 (D13-110) for 15 minutes and chromogen for 5 minutes according to protocol data sheet.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d13-110-102.jpg?browse)
![Human tonsil with rabbit anti FoxP1 (clone EP137) using Polink1 ([D13-60]) rabbit polymer detection and HIER Accel ([B22C-125])for was used 10 minutes pressure cooker. Primary antibody was incubated 1 hour; Polink-1 ([D13-60]) for 15 minutes and chromogen for 5 minutes according to protocol data sheet.](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d13-110-1.jpg?browse)
![IHC staining of FFPE human tonsil tissue within normal limits using mouse anti-human B cell polyclonal antibody and Polink-2 Plus HRP Mouse for DAB detection kit [D37-18]. The brown stain indicates positive stain and blue is the counter stain. It is mounted using a permanent organic mounting medium [E37-100].](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d37.jpg?browse)


![IHC staining of FFPE human breast cancer tissue using mouse anti-ER polyclonal antibody and Polink-2 HRP Broad for DAB detection kit [D22-18]. The brown stain indicates positive stain and blue is the counter stain. It is mounted using a permanent organic mounting medium [E37-100].](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d22.jpg?browse)
![Human placenta screened with OriGene's Ms anti PDL1 ([UM800120] @ 1:100). HIER buffer TEE ([B21-100]) was used in pressure cooker. Secondary Polink 2 HRP Broad without DAB Chromogen (D22-110) was use according to protocol data sheet. Cytoplasmic and membrane stain was visualized with DAB chromogen ([C09-12]).](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d22-110-100-h.jpg?browse)
![Human placenta screened with OriGene's Rb anti PDL1 ([TA591003] @ 1:100). HIER buffer TEE ([B21-100]) was used in pressure cooker. Secondary Polink 2 HRP Broad without DAB Chromogen (D22-110) was use according to protocol data sheet. Cytoplasmic and membrane stain was visualized with DAB chromogen ([C09-12]).](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d22-110-101-h.jpg?browse)
![Human tonsil screened with OriGene's Ms anti Ki67 ([UM800033] @ 1:1000). HIER buffer TEE ([B21-100]) was used in pressure cooker. Secondary Polink 2 HRP Broad without DAB Chromogen (D22-110) was use according to protocol data sheet. Nuclear stain was visualized with DAB chromogen ([C09-12]).](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d22-110-102-h.jpg?browse)
![Human tonsil screened with Epitomics' Rb anti P63 (AC0157RUO @ 1:200). HIER buffer TEE ([B21-100]) was used in pressure cooker. Secondary Polink 2 HRP Broad without DAB Chromogen (D22-110) was use according to protocol data sheet. Nuclear stain was visualized with DAB chromogen ([C09-12]).](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d22-110-103-h.jpg?browse)

![Human tonsil screened with DAKO's Rb anti CD3 (A-0452 @ 1:100). HIER buffer TEE ([B21-100]) was used in pressure cooker. Secondary Polink 1 AP Rabbit without Chromogen (D19-110) was use according to protocol data sheet. Cytoplasmic and membrane stain was visualized with GBI permanent red chromogen ([C13-120]).](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d19-110-100-h.jpg?browse)
![Human tonsil screened with Epitomics Rb anti p63 (AC0157RUO @ 1:100). HIER buffer TEE ([B21-100]) was used in pressure cooker. Secondary Polink 1 AP Rabbit without Chromogen (D19-110) was use according to protocol data sheet. Cytoplasmic and membrane stain was visualized with GBI permanent red chromogen ([C13-120]).](https://cdn.origene.com/catalog/product/assets/images/assay-kit/ihc-kit-and-reagent/151/d19-110-101-h.jpg?browse)

